Cable Coaxial en Bobina 100 m


  • Fecha estimada de entrega:
  • Recíbelo en 5 días - Compra hoy y recíbelo el Jueves, 9 Mayo, 2024
Marca:Macab
EAN13:8424450187692
Referencia:F4151243
85,49 €
Impuestos incluidos
Agotado

  • Envíos Gratuitos

    En pedidos superiores a 30€

  • Envíos Rápidos

    En 24/48 horas

  • Pago 100% Seguro

    Admitimos PayPal

This is A / LSNH Dca-Classified (s1, d1, a1) with a 58% screen interface.
Also has UV protection and limited moisture protection.
- Eca (PVC) cables can be used for installation in buildings less than 200 sq.m., as well as in other buildings where there is a sprinkler system (but no escape routes).
- Dca (LSNH) cables can be used in all buildings, including in escape routes with sprinkler systems.
Macab's triple-shielded cables first have a foil, glued to dielectric. This film shields strongly against high frequencies. On top of the foil is an aluminum braid with at least 58% coverage. This mainly shields the low frequencies. Finally, another aluminum foil lies against the outer sheath of the cable. The glued foil prevents the screen from being pushed back and simplifies the connection. The screen attenuation depends on the cable type and is at least 85 dB across the entire spectrum of spectrum.
- Covered by the latest standard IEC50575.
- Copper gives lower resistance than the cheaper copper wire.
- Gas-injected foam gives longer life and lower damping.
- Laminated foil provides better screen capabilities, especially at high frequencies.
- Easier mounting of contacts.
- Overlapped foil provides even better screen damping and an extra moisture barrier.
- PVC, PE or halogen free mantle depending on installation environment.
- Better noise protection on return
- Low loop resistance.
This is A / LSNH Dca-Classified (s1, d1, a1) with a 58% screen interface.
Also has UV protection and limited moisture protection.
- Eca (PVC) cables can be used for installation in buildings less than 200 sq.m., as well as in other buildings where there is a sprinkler system (but no escape routes).
- Dca (LSNH) cables can be used in all buildings, including in escape routes with sprinkler systems.
Macab's triple-shielded cables first have a foil, glued to dielectric. This film shields strongly against high frequencies. On top of the foil is an aluminum braid with at least 58% coverage. This mainly shields the low frequencies. Finally, another aluminum foil lies against the outer sheath of the cable. The glued foil prevents the screen from being pushed back and simplifies the connection. The screen attenuation depends on the cable type and is at least 85 dB across the entire spectrum of spectrum.
- Covered by the latest standard IEC50575.
- Copper gives lower resistance than the cheaper copper wire.
- Gas-injected foam gives longer life and lower damping.
- Laminated foil provides better screen capabilities, especially at high frequencies.
- Easier mounting of contacts.
- Overlapped foil provides even better screen damping and an extra moisture barrier.
- PVC, PE or halogen free mantle depending on installation environment.
- Better noise protection on return
- Low loop resistance.
Denna är A/LSNH Dca-klassad (s1, d1, a1) med en skärmfläta på 58%.
Har även UV-skydd och ett begränsat fuktskydd.
Hel förpackning är på 4 x 100 meter.
- Eca (PVC) kablar kan användas för installation i byggnader mindre än 200kvm, samt i övriga byggnader där det finns ett sprinklersystem (dock ej utrymningsvägar).
- Dca (LSNH) kablar kan användas i alla byggnader, inklusive i utrymningsvägar med sprinklersystem.
Macab’s trippelskärmade kablar har först en folie, limmad mot dielektrikat. Denna folie avskärmar kraftigt mot höga frekvenser. Ovanpå folien ligger en aluminiumfläta med minst 58% täckning. Denna avskärmar framför allt de låga frekvenserna. Slutligen ligger ytterligare en aluminiumfolie an mot kabelns yttermantel. Den limmade folien förhindrar att skärmen trycks tillbaka och förenklar kontakteringen. Skärmdämpningen är beroende på kabel-typ och är minimum 85 dB över hela frekvensspektrat.
- Omfattas av senaste standard IEC50575.
- Koppar ger lägre resistans än den billigare förkopprade ståltråden.
- Gasinjicerat skum ger längre livslängd och lägre dämpning.
- Limmad folie ger bättre skärmegenskaper, framförallt vid höga frekvenser.
- Enklare montering av kontakter.
- Överlappad folie ger ännu bättre skärmdämpning och en extra fuktspärr.
- PVC, PE eller halogenfri mantel beroende på installations miljö.
- Bättre störskydd på returbandet.
- Låg slingresistans.
- Hög åldringsbeständighet på ingående plaster.
Especificaciones:
Embalaje y empaquetado Carrete
Longitud: 100 m
Material del conductor Cobre

This is A / LSNH Dca-Classified (s1, d1, a1) with a 58% screen interface.
Also has UV protection and limited moisture protection.
- Eca (PVC
Macab
F4151243

Referencias específicas

8 otro producto

Cable Coaxial en Bobina 100 m

85,49 €